Location and Shape of Mental Foramen in Patients Reporting to Saidu College of Dentistry- A Cone Beam Computed Tomography Based Study
DOI:
https://doi.org/10.52206/jsmc.2025.15.4.1259Abstract
Background: The mental foramen (MF) is a critical anatomical landmark in dentistry and maxillofacial surgery due to its role in transmitting the mental nerve, which provides sensory innervation to the lower lip, chin, and adjacent structures. Precise identification of its location and morphology is essential for procedures such as implant placement, nerve block anesthesia, and surgical interventions.
Objective: To determine the location, shape, and dimensional characteristics of the mental foramen using cone-beam computed tomography (CBCT) in a Pakistani population.
Methodology: This cross-sectional study was conducted at the Radiology Department of Saidu College of Dentistry, Swat, from May to September 2024. A total of 164 CBCT scans (83 males, 81 females) were analyzed. The horizontal and vertical diameters of MF were measured, and its morphology was classified according to the horizontal-to-vertical (H:V) ratio. Horizontal and vertical positions of the MF were recorded relative to adjacent teeth and premolar apices. Data were analyzed using SPSS version 20, applying Mann-Whitney U, Kruskal-Wallis, and Fisher’s exact tests with a significance level of p < 0.05.
Results: The mean horizontal and vertical diameters of MF were 2.57 ± 0.57 mm and 2.94 ± 0.83 mm, respectively, with an average H:V ratio of 0.90 ± 0.23. Significant age-related differences were observed in horizontal diameters (p < 0.001) and H:V ratio on the left side (p = 0.014). Males demonstrated significantly greater vertical diameters (p = 0.026) and H:V ratios (p < 0.001) compared to females. Type II (oval-vertical) was the least frequent MF morphology, while Type I (oval-horizontal) and Type III (round) were more common. The MF was most often located horizontally between the first and second premolars and vertically below the apices of mandibular premolars.
Conclusion: CBCT imaging revealed significant variations in MF morphology based on age and gender in the Pakistani population, while positional patterns remained largely consistent. These findings highlight the importance of preoperative CBCT assessment to avoid neurosensory complications during dental and surgical procedures.
Keywords: Anatomical variation, Cone-beam computed tomography, Dental implantology, Mental foramen, Pakistani population.
References
Almeida D, Mesquita LR, Maria M, Santiago D, Samuel F, Kurita LM, et al. Mental foramen and anterior loop anatomic characteristics: a systematic review and meta-analysis of cross-sectional imaging studies. J Endod. 2021;47(12):1829–1843.e1. http://doi.org/10.1016/j.joen.2021.08.006
Al-Shayyab MH, Ryalat S, Dar-Odeh N. The mental foramen I: Radiographic study of the morphological and morphometric variations of the mental foramen in health and disease. BMC Med Imaging. 2019;19(1):1–9. http://doi.org/10.1186/s12880-019-0314-0
Ngeow WC, Yuzawati Y. The location of the mental foramen in a selected Malay population. J Oral Sci. 2003;45(3):171–175. http://doi.org/10.2334/josnusd.45.171
Bahamid A, Alsaif SY, Almansouri AS, Alshammari M, Alshahrani FA, Alhusayni A. Mental foramen position, shape, continuity, and symmetry among malocclusion patients: a radiographic study. Cureus. 2023;15(12):e51056. http://doi.org/10.7759/cureus.51056
Taschieri S, Vitelli C, Albano D, Sconfienza LM, Del Fabbro M, Francetti L, et al. Evaluation of mental foramen and inferior alveolar nerve canal and its relationship to adjacent anatomical landmarks using cone-beam computed tomography. J Biol Regul Homeost Agents. 2021;35(Suppl 1):107–115. http://doi.org/10.23812/21-2supp1-10
Othman B, Zahid T. Mental nerve anterior loop detection in panoramic and cone-beam computed tomography radiograph for safe dental implant placement. Cureus. 2022;14(10):e30687. http://doi.org/10.7759/cureus.30687
Jamil Y, Rehman AZ, Alam S. Assessment of variations in the location of mental foramen by means of cone beam computed tomography. Isra Med J. 2020;12(4):215–218.
Salam S, Zia A, Alam S, Irshad M. Relative position of mandibular third molar and inferior alveolar nerve using cone beam computed tomography. ResearchGate. 2023. Available from: https://www.researchgate.net/publication/370923084
Zmys?owska-Polakowska E, Radziszewska A, ??ski M. Evaluation of the position of the mental foramen in the Polish population using cone-beam computed tomography. Biomed Res Int. 2019;2019:1659476. http://doi.org/10.1155/2019/1659476
Saeed T, Tayyab TF, Liaquat A, Akram MA, Riaz N, Abdulhannan H. Evaluation of location of mental foramen using cone-beam computed tomography in Pakistani population. Prof Med J. 2021;28(9):1341–1345. http://doi.org/10.29309/tpmj/2021.28.09.6111
Alam BF, Yusof A, Ali Shah S, Abdullah JY, Awang Nawi MA. Morphometric analysis of the dimension and distance to anatomical structures from the mental foramen using cone beam computed tomography. Cureus. 2024;16(10):e71496. http://doi.org/10.7759/cureus.71496
Ghandourah AO, Badaoud MB, Dahlawi A, Alghamdi A, Alhazmi F, Sembawa SN, et al. A radiographic analysis of the location of the mental foramen. Saudi Dent J. 2023;35(4):354–358. http://doi.org/10.1016/j.sdentj.2023.03.001
Ahmed AA, Ahmed RM, Jamleh A, Spagnuolo G. Morphometric analysis of the mandibular canal, anterior loop, and mental foramen: a cone-beam computed tomography evaluation. Int J Environ Res Public Health. 2021;18(7):3365. http://doi.org/10.3390/ijerph18073365
Motiwala MA, Javed F, Ghafoor R. Cone beam computed tomography-based evaluation of position of mental foramen and its relation to apices of mandibular posterior teeth in a sample of Pakistani population. J Pak Med Assoc. 2022;72(10):1963–1967. http://doi.org/10.47391/JPMA.3358
Coban D, Unal Erzurumlu Z, Sadik E, Yasa Y. Evaluation of mental foramen and accessory mental foramen using cone-beam computed tomography in a Turkish population. BMC Med Imaging. 2025;25(1):15. http://doi.org/10.1186/s12880-025-01589-1
Saeed T, Tayyab TF, Liaquat A, Akram MA, Riaz N, Abdulhannan H. Evaluation of location of mental foramen using cone-beam computed tomography in Pakistani population. Prof Med J. 2021;28(9):1341–1345. http://doi.org/10.29309/tpmj/2021.28.09.6111
Yu SK, Lim J, Bae CJ, Seo YS, Kim HJ. Morphometric analysis of the mandibular lingual foramina using cone-beam computed tomography in elderly Korean. Int J Morphol. 2022;40(3):688–696. http://doi.org/10.4067/s0717-95022022000300688
Parmar A, Shah K, Patel B, Jadav J, Trivedi B, Kothari G. Morphological and morphometric analysis of mental foramen in dry human mandibles. Int J Med Sci Public Health. 2013;2(3):654–657. http://doi.org/10.5455/ijmsph.2013.240420131
Zaman S, Alam MK, Yusa T, Mukai A, Shoumura M, Rahman SA, et al. Mental foramen position using modified assessment system: an imperative landmark for implant and orthognathic surgery. J Hard Tissue Biol. 2016;25(4):365–370. http://doi.org/10.2485/jhtb.25.365
Pelé A, Berry PA, Evanno C, Jordana F. Evaluation of mental foramen with cone beam computed tomography: a systematic review of literature. Radiol Res Pract. 2021;2021:8897275.http://doi.org/10.1155/2021/8897275
AlOtaibi MG, Tawfig A, Abouelkheir HM. Evaluation of shape, size, and location of mental foramen in dentulous and edentulous among Saudi population using 3D cone-beam computed tomography. F1000Res. 2022;11:916. http://doi.org/10.12688/f1000research.74434.2
Additional Files
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 The authors retain the copyrights. Authors are permitted and encouraged to post their work online (e.g. in institutional repositories or on their website), as it can lead to productive exchanges, as well as greater citation of published work.

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Readers may “Share-copy and redistribute the material in any medium or format” and “Adapt-remix, transform, and build upon the material”. The readers must give appropriate credit to the source of the material and indicate if changes were made to the material. Readers may not use the material for commercial purpose. The readers may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.



